This HIPAA risk assessment template is a free workbook for the Security Rule risk analysis1. It has a sheet for listing where ePHI is kept, a risk register scored on the five-level scale in NIST's guide, and a compliance checklist with one row for each Security Rule standard and implementation specification12. It is a working structure to fill in. It is not an official form.
Download the HIPAA risk assessment template
What is in the file
The workbook has seven sheets. They follow the steps in section 3.2 of NIST SP 800-66 Revision 2, which is NIST's guide to the Security Rule2.
| Sheet | NIST step it supports2 | What goes in it |
|---|---|---|
| Read me | Organization, security official, assessment period, how to use the file | |
| ePHI locations | Prepare for the assessment | One row per system, share, device or export that holds ePHI, and how you know |
| Scan coverage | Prepare for the assessment | Each file scan used as evidence, and what it could not read |
| Risk register | Identify threats and vulnerabilities, rate likelihood and impact, set the level of risk | One row per threat and vulnerability pair |
| Risk matrix | Determine the level of risk | The lookup table the register reads |
| Safeguards | The HIPAA compliance checklist: every standard and specification | |
| Review log | Document the results | Each version, who approved it, what triggers the next review |
NIST is clear that the method is a choice. It says HHS OCR "does not prescribe any particular risk assessment or risk management methodology" and that there is no single method that suits every organization2. Change the columns to fit.
How to fill in the ePHI section
Start here, before any risk is rated. NIST's first step says an organization should understand where ePHI is created and received, where it is stored and where it leaves, before it identifies threats2.
Give each place its own row: the records system, each shared folder, workstations, laptops, removable media, mailbox exports, cloud services and devices. NIST asks that the scope cover removable media and portable devices as well as networked systems2. For each row, record what kinds of ePHI are there, who can reach it and whether it is encrypted.
One column does most of the work. "How identified" takes one of five answers: file scan report, system documentation, interview, manual review, or not yet reviewed. The last one turns red. A folder nobody has opened should say so until somebody has.
The Scan coverage sheet sits beside it. If a scan was used as evidence, log its scope, its date and the tool and version, then write down what it could not read. Whatever a scan did not open has not been reviewed.
How the risk register scores risk
Each row pairs a threat with a vulnerability and points back to a location ID. Threat source is a drop-down with NIST's categories of natural, human and environmental2. Likelihood and impact each take one of five levels, and the risk level fills in from the matrix sheet.
The matrix is the detailed example in NIST's guide2. Rows are threat likelihood and columns are level of impact:
| Likelihood | Very Low | Low | Moderate | High | Very High |
|---|---|---|---|---|---|
| Very High | Very Low | Low | Moderate | High | Very High |
| High | Very Low | Low | Moderate | High | Very High |
| Moderate | Very Low | Low | Moderate | Moderate | High |
| Low | Very Low | Low | Low | Low | Moderate |
| Very Low | Very Low | Very Low | Very Low | Low | Low |
NIST says organizations can use a different matrix that fits their own rating scales2. The cells on the matrix sheet are editable for that reason.
The register is also the report. NIST's last step is to document all threat and vulnerability pairs, the likelihood and impact ratings and the overall risk for each pair, and it suggests a risk register as the format2. It points to Appendix K of NIST SP 800-30 for a sample report outline2.
The HIPAA compliance checklist sheet
The Safeguards sheet lists each standard and implementation specification in the Security Rule under the regulation's own heading, with its "Required" or "Addressable" label. Every row gets a status, an evidence note, an owner and a due date.
| Section | Standard | Required specifications | Addressable specifications |
|---|---|---|---|
| 164.308(a)(1)1 | Security management process | Risk analysis, risk management, sanction policy, information system activity review | |
| 164.308(a)(2)1 | Assigned security responsibility | ||
| 164.308(a)(3)1 | Workforce security | Authorization and/or supervision, workforce clearance procedure, termination procedures | |
| 164.308(a)(4)1 | Information access management | Isolating health care clearinghouse functions | Access authorization, access establishment and modification |
| 164.308(a)(5)1 | Security awareness and training | Security reminders, protection from malicious software, log-in monitoring, password management | |
| 164.308(a)(6)1 | Security incident procedures | Response and reporting | |
| 164.308(a)(7)1 | Contingency plan | Data backup plan, disaster recovery plan, emergency mode operation plan | Testing and revision procedures, applications and data criticality analysis |
| 164.308(a)(8)1 | Evaluation | ||
| 164.308(b)1 | Business associate contracts and other arrangements | Written contract or other arrangement | |
| 164.310(a)5 | Facility access controls | Contingency operations, facility security plan, access control and validation procedures, maintenance records | |
| 164.310(b)5 | Workstation use | ||
| 164.310(c)5 | Workstation security | ||
| 164.310(d)5 | Device and media controls | Disposal, media re-use | Accountability, data backup and storage |
| 164.312(a)6 | Access control | Unique user identification, emergency access procedure | Automatic logoff, encryption and decryption |
| 164.312(b)6 | Audit controls | ||
| 164.312(c)6 | Integrity | Mechanism to authenticate electronic protected health information | |
| 164.312(d)6 | Person or entity authentication | ||
| 164.312(e)6 | Transmission security | Integrity controls, encryption | |
| 164.314(a)7 | Business associate contracts or other arrangements | Its implementation specifications | |
| 164.314(b)7 | Requirements for group health plans | Its implementation specifications | |
| 164.316(a)4 | Policies and procedures | ||
| 164.316(b)4 | Documentation | Time limit, availability, updates |
The sheet gives the names only. Read the paragraph itself before marking a row done.
Addressable rows have two extra columns. When an addressable specification is not reasonable and appropriate for the organization, the rule asks it to document why and to implement an equivalent alternative measure if that is reasonable and appropriate3. The columns hold the reason and the alternative.
Keeping the finished assessment
The Review log records each completed version. The Security Rule requires documentation to be retained for 6 years from its creation or from the date it was last in effect, whichever is later, and to be reviewed periodically and updated as needed when operations or the environment change4. NIST adds that a risk assessment is "an ongoing activity" and should be updated on a periodic basis2.
This template or the HHS SRA Tool?
They suit different habits. The SRA Tool from ONC and the HHS Office for Civil Rights is a guided questionnaire aimed at "medium and small providers", with a Windows application and a workbook version8. HealthIT.gov says the tool is for informational purposes and that its use is not required8. This template is a blank structure organized around where the ePHI is. Some practices answer the SRA Tool's questions and keep this file as the location list and risk register behind the answers.
Filling the ePHI sheet from a scan
The "file scan report" answer in the location sheet needs a report behind it. VellumSoft scans PST and email exports, documents and images for US and Canadian PII and PHI, runs locally, and exports a PDF report plus a CSV of findings. The report includes a coverage disclosure of what the scan could not read, which is what the Scan coverage sheet is for.
One limit applies to this file directly. Version 2.0.2 does not read XLSX workbooks, Word (DOCX) files, or ZIP and 7z archives. A filled-in copy of this template will not be scanned, and neither will other files in those formats, so list them under "Formats or items not reviewed". No scanner finds everything.
The full method is on the page about finding ePHI for a HIPAA risk analysis, and how it works covers the scan itself. Other free files are listed under templates page: PII inventory, the WISP template for tax preparers, the FTC Safeguards checklist and breach response plan.
Fill in the first ten rows of the ePHI locations sheet from memory, then check one of them. The gap between the two is the reason the sheet exists.
This page explains the law in general terms and is not legal advice.
Questions
Is there an official HIPAA risk assessment form?
No. NIST's guide to the Security Rule says HHS OCR does not prescribe any particular risk assessment or risk management methodology. HHS and ONC publish the Security Risk Assessment Tool for small and medium providers, and HealthIT.gov says using it is not required. Any format works if the assessment is accurate and thorough, and is written down.
What should a HIPAA risk assessment report contain?
NIST says to document every threat and vulnerability pair that applies to the organization, the likelihood and impact ratings, and the overall risk to ePHI for each pair. It suggests a risk register as the format. This template adds the list of ePHI locations the ratings are based on and a log of each review.
Is a HIPAA compliance checklist the same as a risk assessment?
No. A checklist asks whether each Security Rule standard has been met. A risk assessment asks what could go wrong with the ePHI you hold and how likely and how serious it would be. The risk analysis is one required row on the checklist, which is why this file holds both.
How long should a completed risk assessment be kept?
For 6 years. The Security Rule's documentation standard says required documentation must be retained for 6 years from the date of its creation or the date when it last was in effect, whichever is later. Save a dated copy of each version.
Sources
- eCFR, 45 CFR 164.308, Administrative safeguardsReviewed 16 Nov 2026
- eCFR, 45 CFR 164.306, Security standards: General rulesReviewed 16 Nov 2026
- eCFR, 45 CFR 164.316, Policies and procedures and documentation requirementsReviewed 16 Nov 2026
- eCFR, 45 CFR 164.310, Physical safeguardsReviewed 16 Nov 2026
- eCFR, 45 CFR 164.312, Technical safeguardsReviewed 16 Nov 2026
- eCFR, 45 CFR 164.314, Organizational requirementsReviewed 16 Nov 2026
- HealthIT.gov (ONC), Security Risk Assessment ToolReviewed 16 Nov 2026